RF power amplifier line-ups from bare dies
Give a band and an output power. GeneratedWave picks commercial bare dies, works out how many to combine, chooses the drivers, designs the combiner and reports output power, gain, efficiency, VSWR and junction temperature over the base-plate temperatures. The catalogue holds 963 bare dies of 30 vendors, 308 of them power amplifiers and 234 drivers, each with the page or datasheet its numbers came from.
What goes in and what comes out
In
- Band and output power in W or dBm
- Input level or gain
- Least PAE, most supply power, highest rail
- Largest input and output VSWR
- CW or pulsed, back-off, vendors, parts to leave out
- Combiner substrate: alumina, AlN or RO4003C
Out
- Every stage: part, number of dies, drive, headroom, heat
- Output power at −40, 25 and 70 °C base plate
- What nine builds in ten reach, and what is left with one die dead
- Combiner line widths, lengths and resistors, with a GDS drawing
- Each limit met, missed or open when the datasheet does not say
Worked example: 100 W from 6 to 12 GHz
Asked for: 100 W over 6 to 12 GHz from a 10 dBm source. The answer is four Qorvo TGA2590 dies on a two-level tree of two-section Wilkinson combiners, driven by one QPA1013D, behind a 1 dB input pad: five dies in all.
- Output at 25 °C
- 138 W
- Output at 70 °C
- 112 W
- Output at −40 °C
- 186 W, with the drive lowered to −0.1 dBm
- Nine builds in ten, 25 °C
- ≥ 124 W
- One die dead, 25 °C
- 78 W
- Drive needed at the input connector, 70 °C
- 10.0 dBm, the 10 dBm limit: no margin
- PAE, 25 °C
- 26.6 %
- Supply power, 25 °C
- 519 W
- Combiner loss
- 0.62 dB
- Output VSWR
- 1.88
- Hottest junction, 70 °C plate
- 157 °C, limit 275 °C
The 157 °C junction counts each output die’s heat at 70 °C, about 67 W, which falls with its output; at its 25 °C dissipation, 82 W, it would be about 177 °C, still under 275 °C.
Inputs of this run: 6 to 12 GHz, 100 W CW, 10 dBm source, base plate −40, 25 and 70 °C, combiner chosen automatically on 10 mil alumina, each die’s power and phase spread 0.5 dB and 10° (one sigma, assumed) over 400 draws, the die catalogue of 25 November 2026, every other input at its default. TGA2590’s datasheet does not say whether its 46 dBm is CW or pulsed: check that before counting on it CW.
With quadrature couplers the same four dies give 144 W and an output VSWR of 1.00 instead of 1.88, behind a 0.5 dB pad instead of 1 dB.
The line-up is sized at the hottest base plate, where every die gives its least power and gain. That is why 100 W asked becomes 138 W at room temperature.
How the figures are made
- Dies run at their datasheet power and at the gain the datasheet gives for that power; without one, 8 dB under small-signal gain at saturation
- Combiners are analysed from S-parameters with lossy lines, not a fixed loss
- Dies scatter by 0.5 dB and 10° (one sigma) over 400 draws for the production figure
- Temperature drift comes from each datasheet, or a stated default when the datasheet has none
- Junction temperature uses the datasheet’s thermal resistance, or an estimate marked as one
- 341 of the 963 rows have been checked line by line against the part’s own datasheet
What it does not do
- No load-pull: the combiner is taken to present 50 Ω to every die
- No gain slope or phase of the dies over frequency
- The combiner tree as a whole has not been simulated in full wave; two-way Wilkinsons on RO4003C have
- No carrier or housing thermal design under the base plate
- Most catalogue rows are typical values; check CW or pulsed rating in the datasheet
Questions
How many dies does a 100 W amplifier from 6 to 12 GHz need?
Four TGA2590 dies in this model. Each gives 46 dBm, about 40 W, at 25 °C before the combiner’s loss, and about 44.5 dBm after it on a 70 °C base plate. Together they give 138 W at 25 °C and 112 W at 70 °C.
Should the dies be combined with Wilkinsons or quadrature couplers?
A Wilkinson tree passes the dies’ own mismatch to the output, here a VSWR of 1.88. A quadrature tree sends it into terminations and shows about 1.0 in an ideal model. When an output VSWR limit is given, the in-phase tree is tried first and the quadrature one when it does not keep the limit.
What is left when one die fails?
In the four-die example 78 W of 138 W. The loss is more than a quarter because the dead branch unbalances the tree and the difference is burnt in the isolation resistors.